Amenities |
- State of the art infrastructure facilities.
- Gym, health clubs & child care.
- Restaurants, food court & cafeteria.
- Retail outlets & ATM.
- 3 Level basement parking
- 1600 covered car parks
- Centrally air conditioned
- 100% Power backup
- CCTV Security
- Plush Finished Lobbies.
- High Speed Elevators
- Multiple Kiosks
|
Specifications |
General Arrangement |
- The complex has been designed as a campus arranged around a landscaped podium and an elevated green deck. While the office blocks vary in heights from G+13 to G+11 with varying floor plate sizes, the ground floor has been designed to accommodate corporate and retail spaces and eateries.
|
About Office Blocks |
Office Spaces |
- Office modules of various sizes.
- Offices designed around central core areas as well as side cores to ensure excellent quality of natural light and views all round.
|
Floor To Floor Height |
- 3.85 mts on typical floors.
- 5.0 mts on ground floor
|
Approach and Access |
- Separate drop offs for all the blocks with dedicated entrance lobbies.
|
Facilities and Amenities |
- Well designed entrance lobby at ground floor.
- Passenger elevators designed to cater for the expected traffic.
- Dedicated service lift for movement of goods and materials.
- Common toilet facilities provided on each floor.
|
Finishes |
Lobbies and Common Spaces and Common Toilets |
- Finished in a combination of architecturally pleasing materials such as stone, high quality tiles, wall and ceiling finishes.
|
Tenant Space |
- Adequate finishing margin shall be left on the floor for client fit out works
|
External Facade and Finishes |
- A combination of architecturally designed external facade finishes in modern and contemporary materials.
- Double glazed aluminum windows and fenestration along with curtain glass in locations according to elevation requirements.
|
Signage |
- Client directory signage in main entrance lobby on ground floor.
- Client directory signage on each office floor.
|
Parking |
- Multi Level Basements to accommodate approximately 1600 cars.
- Provision for surface parking and drop off areas.
|
Structure |
- Capital slab arrangement in office floors with clear height of 3.6 mts.
- RCC structure designed in strict compliance with all requirements of the Seismic Zone 4 as prescribed in the Indian Standard Code.
|
Electrical Systems and Installations |
Normal Power Source |
- Power Supply from the DHVBNL shall be made available.
|
Power Back Up |
- 100% power backup through DG sets designed and installed in compliance with stringent emission norms.
|
Power Distribution |
- Power supply cables shall be drawn to the tenant's distribution board.
|
Metering |
- Dual energy meters installed for each tenant to measure consumption of normal power and backup power supply separately.
|
Communications |
- Adequate provisions for Telephone, Voice and Data connectivity through multiple service providers.
|
Earthing |
- Infrastructure and necessary installations will be provided.
|
Lighting And Illumination |
- Lighting and illumination of common areas as well as external areas designed scientifically to appropriate lux levels.
- Adequate provision for critical lighting in areas of circulation and emergency usage.
- Architectural lighting to illuminate the complex to enhance its usability and footfalls.
|
Hvac Systems |
Corporate Retail Areas and Office Blocks |
- Office space shall be air-conditioned through highly energy efficient central A.C. system with BMS.
|
Basements |
- Mechanical Ventilation system in strict compliance with NBC norms.
|
Fire and Life Safety |
Fire Detection System |
- Provided in accordance with the Fire Safety norms as per the NBC
|
Fire Fighting and Suppression |
- Wet Risers, Fire Hose reels, Fire Extinguishers and Sprinklers – provided as per norms. Yard Hydrants and Firefighting pumps installed at lower levels as per the NBC norms along with dedicated Fire Tanks.
|
Fire Escape |
- Provision for Fire Exits and Escape Stairs at appropriate locations in accordance with the NBC.
|
Plumbing Installations |
Water Supply Systems |
- Designed to stringent standards and norms for public health and hygiene.
|
Waste Water and Sewer Systems |
- As per public health and sanitation standards and norms.
|
Rain Water Harvesting |
- Rain water will be collected through network of pipes and installations and recharged into ground aquifers in compliance with the norms.
|
Security |
Specifications |
- Main Entrance
- Main Lift Lobby
- Basement Lift Lobbies/Ramps
- Staircases
|
Manned Security |
- Check posts at key locations within the complex. Boom Barriers at basement entry and exits.
|
*Disclaimer:- Specifications are indicative and are subjected to change as decided by the architect. Minor variations may be required during execution of work. The Applicants/Allottees do not bear any right to raise any objections in this regard |